[PIE] LOOP CALIBRATOR PIECAL 434
Automated 4-20mA Loop Calibrator with Loop Diagnostics
제품특징
Calibrate Milliamp Instruments: Source 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA Read 0.000 to 24.000 mA & -25.00 to 125.00% of 4-20 mA Read -99.99 to 99.99 V Simulate 2-Wire Transmitter, Power & Read Transmitters Menu Selectable 250 Ohm resistor for HART compatibility
Calibrate with Lab Accuracy: Accurate to ±(0.01% of Reading + 0.002 mA) PIECAL 434 is more accurate than similar calibrators - within ±0.004 mA at 20 mA output!
Easy-to-Read Backlit Display
Locate Loop Current Leakages: Automatic indication of Loop Current and Leakage Current. Measure ground current leakage from faulty wiring, flooded conduit and corrosion bridges. Leakage typically appears as a Zero Shift and helps you decide if the transmitter needs calibration or if there is a problem in the loop wiring.
Faster Calibrations: Three output EZ-CHECK switch 2 speed EZ-DIAL Stepping & Ramping
Includes Rubber Boot, Test Leads and hands free carrying case
제품사양
|
PIECAL 434 Specifications | |
| General | |
| Operating Temperature Range | -20 to 60 °C (-5 to 140 °F) |
| Storage Temperature Range | -30 to 60 °C (-22 to 140 °F) |
| Relative Humidity Range | 10 % =RH =90 % (0 to 35 °C), Non-condensing |
| 10 % =RH= 70 % (35 to 60 °C), Non-condensing | |
| Size | 5.63 x 3.00 x 1.60 in, 143 x 76 x 41mm (LxWxH) |
| Weight | 12.1 ounces, 0.34 kg (including boot & batteries) |
| Batteries | Four “AA” Alkaline 1.5V (LR6) |
| Optional AC Adaptors | 120 VAC 50/60 Hz [Part # 020-0100] |
| 240 VAC 50/60 Hz [Part # 020-0101] | |
| Optional NiMh Rechargeable battery kit | 120 VAC for North America Only; charger, four NiMh batteries, AC & DC cords [Part # 020-0103] |
| Low Battery | Low battery indication with nominal 1 hour of operation left |
| Protection against misconnection | Over-voltage protection to 135 vrms (rated for 30 seconds) or 240 vrms (rated for 15 seconds) |
| Display | High contrast graphic liquid crystal display with 0.315” (8.0 mm) high digits. LED backlighting for use in low lit areas. |
| Read mA | |
| Ranges and Resolution | 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA |
| Accuracy | = ± (0.01 % of Reading +0.002 mA) |
| Voltage burden | = 2V at 50 mA |
| Overload/Current limit protection | 25 mA nominal |
| Battery life | = 125 Hours nominal |
| = 100 hrs with backlight on | |
| Source/Power & Measure Two Wire Transmitters | |
| Ranges and Resolution | 0.000 to 24.000 mA or -25.00 to 125.00% of 4-20 mA |
| Accuracy | = ± (0.01 % of Reading +0.002 mA) |
| Noise | = ± ½ Least Significant Digit |
| Temperature effect | = ± 0.005 %/°C of FS |
| Loop compliance voltage | = 24 DCV @ 20.00mA |
| Loop drive capability - Leak Detection Off | 1200 O at 20 mA for 15 hours nominal; 950 O with Hart Resistor enabled |
| Loop drive capability - Leak Detection On | 1000 O at 20 mA for 15 hours nominal; 750 O with Hart Resistor enabled |
| Battery life | = 30 hrs at 12 mA nominal; = 25 hrs with backlight on |
| 2-Wire Transmitter Simulation | |
| Accuracy | Same as Source/Power & Measure |
| Voltage burden | = 2V at 20 mA |
| Overload/Current limit protection | 24 mA nominal |
| Loop voltage limits | 2 to 60 VDC (fuse-less protected from reverse polarity connections) |
| Battery life | = 125 hours nominal; = 100 hrs with backlight on |
| Voltage Read | |
| Range and Resolution | -60.00 to +60.00 VDC Full Span (FS) |
| Accuracy | = ± 0.05 % of FS |
| Temperature effect | = ± 100 ppm/°C of FS |
| Input resistance | = 2 MΩ |
| Battery life | = 125 hours nominal; = 100 hrs with backlight on |




![[PIE] LOOP CALIBRATOR PIECAL 434 [PIE] LOOP CALIBRATOR PIECAL 434](https://cdn-saas-web-116-121.cdn-nhncommerce.com/naraetek39_godomall_com/data/goods/16/07/06/2142/1467793676465m0_detail.jpg)