Altek 334A Process Loop Calibrator
All 4 to 20 mA Loop
Functions
Source 0.00 to 24.00 mA or -25.0 to 125.0% read mA or
percent to 52.00 mA, simulate 2-wire transmitters, measure -99.99 to 99.99 volts
DC power & read 2-wire transmitters.
Quik-Check
Switch
Select 4 or 20 mA output or 2-wire simulation. Accurate
to ±0.006 mA.
Full Range 10 Microamp
Resolution
Adjust 4 digit display to ±0.05% without range
change.
Long Battery
Life
3x9
volt alkaline batteries source 20 mA for over 20 hours, 12 mA for over 33 hours;
2-wire simulate and read for 150 hours. Much longer than NiCd batteries or
calibrators with a single 9 V battery!
Drive
Capability
1200 Ohms with current limited, fuseless protection to
135 V AC/DC.
The Altek 334A will
check, calibrate and measure all your current signal instruments in a 4 to 20
milliamp DC loop. Use at every point in your loop. Source & Read 0.00 to
24.00 mA, Simulate a 2-wire transmitter or use the Model 334A to simultaneously
power & measure your 2-wire transmitters. Toggle the display to show
milliamps or percent of 4 to 20.
Calibrate recorders, digital indicators,
stroke valves or any other instruments that get their input from a 4 to 20 mA
loop. Easily set any value to within 0.01 mA with the speed sensitive digital
potentiometer.
The "Quik-Chek" switch provides rapid checking of 4.00,
20.00 and a third point between 0.00 to 24.00 mA.
Check loop wiring and
receivers by using the Model 334A in place of a 2-wire transmitter. Simulate a
changing process input to check loop response and control settings. The Model
334A uses any loop power from 3 to 45V DC.
Check controller outputs or
measure the milliamp signal anywhere in the loop. The Model 334A measures 0.00
to 24.00 mA signals with much greater accuracy than a typical multimeter. Toggle
the display to show milliamps or percent of 4 to 20.
Simultaneously
measure the output of a 2-wire transmitter while using the internal batteries to
supply up to 27V DC to power the transmitter. Handy for checking transmitters in
the field or on the bench.
Measure from -99.99 to 99.99 VDC with 10mV
resolution. Use it to check loop power supplies, I/V converters, 1 to 5 Volt
signals and battery voltages.




![[ALTEK] MA LOOP CALIBRATOR 루프교정기 334A (단종) -> 대체모델 PIE 334 [ALTEK] MA LOOP CALIBRATOR 루프교정기 334A (단종) -> 대체모델 PIE 334](https://cdn-saas-web-116-121.cdn-nhncommerce.com/naraetek39_godomall_com/data/goods/13/04/10/113/1369061032873m0_detail.jpg)