[TES] TES-3040H 클램프메타
제품특징
3-3/4 Digital LCD with bar-graphAuto-Ranging on Volt, Ohm, Current,
Frequency measurements
Auto-power off
Data Hold mode
MAX/MIN Hold mode
Zero Adjustment/Relative Reading
| 기술적세부사항 | ||||||
| AC Current(자동 & 수동 Range):Low Pass Filter | ||||||
| 측정범위 | 분해능 | 정확도 | Overload protection | Frequency Response | ||
| 400A | 0.1A | ±(2% + 10) | 1100A | 40 ~ 450Hz | ||
| 1000A | 1A | |||||
| Additional Crest Factor Errors (non - sinecure) | ||||||
| Crest Factor | Error (% of reading) | |||||
| 1―3 | 0.5% | |||||
| 3―5 | 3% | |||||
| 5―7 | 6% | |||||
| INFLUENCE OUANTITY | ||||||
| Influence quantity | Limits of variation | Measured quantity | Tolerance | |||
| Position of conductor in the clamp conductor’s diameter: 20mm | In relation to the center | Amps | ±(1%+5) | |||
| DC Voltage(자동 & 수동 Range) | ||||||
| 측정범위 | 분해능 | 정확도 | Input impedance | Overload protection | ||
| 400mV | 0.1mV | ±(0.75% + 2 ) | ≒11MΩ | 600Vrms | ||
| 4V | 0.001V | ≒10MΩ | ||||
| 40V | 0.01V | |||||
| 400V | 0.1V | |||||
| 600V | 1V | |||||
| AC Voltage(자동 & 수동 Range): Low Pass Filter | ||||||
| 측정범위 | 분해능 | 정확도 | Input impedance | Overload protection | Frequency Response | |
| 4V | 0.001V | ±(1.2% + 5) | ≒11MΩ | 600Vrms | 40 ~ 450Hz | |
| 40V | 0.01V | ≒10MΩ | ||||
| 400V | 0.1V | |||||
| 600V | 1V | ±(1.5% + 5) | ||||
| Additional Crest Factor Errors (non - sinecure) | ||||||
| Crest Factor | Error (% of reading) | |||||
| 1―3 | 0.5% | |||||
| 3―5 | 3% | |||||
| 5―7 | 6% | |||||
| Frequency(Voltage에서 자동 Range) | ||||||
| 측정범위 | 분해능 | 정확도 | Sensitivity | Overload Protection | ||
| 100Hz | 0.01Hz | ±(0.1% + 2) | 100mV | 600Vrms | ||
| 1KHz | 0.1Hz | |||||
| 5KHZ | 0.001KHz | |||||
| Frequency(Current에서 자동 Range) | ||||||
| 측정범위 | 분해능 | 정확도 | Sensitivity | Overload Protection | ||
| 100Hz | 0.01Hz | ±(0.5% + 5) | 5A | 1100A | ||
| 1KHz | 0.1Hz | |||||
| Resistance(Ω)(자동 & 수동 Range) | ||||||
| 측정범위 | 분해능 | 정확도 | Open circuit Voltage | Overload protection | ||
| 400Ω | 0.1Ω | ±(1% + 5) | ≤0.5 VDC | 600Vrms | ||
| 4KΩ | 0.001KΩ | ±(1% + 3) | ||||
| 40KΩ | 0.01KΩ | |||||
| 400KΩ | 0.1KΩ | |||||
| 4MΩ | 0.001MΩ | |||||
| 40MΩ | 0.01MΩ | ±(1.5% + 3) | ||||
| Audible Continuity | ||||||
| 측정범위 | Continuity beeper | Open Circuit Voltage | Overload Protection | |||
| Bitmap | ≤40Ω | ≤0.5V | 600Vrms | |||
| Diode test | ||||||
| 측정범위 | 분해능 | 정확도 | Overload Protection | |||
| Bitmap | 0.001V | ±(1% + 2) | 600Vrms | |||
| 제품사양 | ||||
| 세부사항 | 내 용 | |||
| 측정범위선택 | All ranges are selected by a single range switch. | |||
| Polarity | Dual Slope Integration | |||
| 표시 | 3-3/4 Digit Liquid Crystal LCD Display Reading 3999 | |||
| 측정범위 초과 표시 | LCD will show a "OL" flashing in the highest position accompanied with a continuous beeping. (except for ranges of 1000A AC, and 600VDC 600VAC ). | |||
| Low battery 표시 | Bitmap
| |||
| Sampling Rate | Barograph | 20 times / sec | ||
| Digital Display | 2 times / sec | |||
| 자동꺼짐기능 | Approx. 30 minutes | |||
| 사용온도/습도 | :0℃ to 50℃(32℉ to 122℉) and Humidity below 80%RH | |||
| 보관온도/습도 | -10℃ to 60℃(14℉ to 140℉) and Humidity below 70%RH | |||
| 전원/수명 | one 006p 9V or IEC 6F22 or NEDA 1604 Battery. / 100hr approx. (Alkaline) | |||
| 크기/무게 | 239mm(L)×66mm(W)×34mm(H) / Approx. 430g | |||
| 기본악세사리 | 사용설명서, Battery, Test leads, Carry Case | |||