Diagnostic Temperature & mA Calibrator PIE 525Plus | RTD , Thermocouple and loop calibrator
제품기능 및특징
Three Calibrators in
One!
Calibrate all your Thermocouple, RTD instruments AND your
milliamp loops with the PIE 525Plus. It has all the functions of a 12 type RTD
calibrator, 14 type thermocouple calibrator and can source 0 to 24 milliamps or
simulate a two wire transmitter like a milliamp calibrator. You may also perform
stand alone calibrations of two wire transmitters by simultaneously supplying
the RTD or thermocouple input signal while supplying the 24 volts to power up
the transmitter and monitoring the milliamp output signal. Powers HART™
transmitters with built-in 250 ohm resistor simplifying hookups with HART
communicators.
Troubleshoot loop
problems
Quickly diagnose ground fault and current leakage with the
patented loop diagnostic technology (US Patent# 7,248,058)
Calibrate directly in
temperature (°C & °F)
Stop carrying around a decade box
and RTD resistance tables. The PIE 525Plus works with the RTDs you use including
Platinum 10, 50, 100, 200, 500 & 1000 Ohm (alpha = 3850), Platinum 100 Ohm
(alpha = 3902, 3916, 3926), Copper 10 & 50 Ohm, and Nickel 120 Ohm. Or
calibrate from 0.000 to 400.000 and 0.00 to 4000.00 Ohms. For RTDs the fixed or
pulsed sensor current is measured by the calibrator. Have thermocouples also?
Choose from J, K, T, E, R, S, B, N, G, C, D, L (J DIN), U (T DIN) or P
(Platinel). Or calibrate from 13.000 to 80.000 mV
Measure RTD
sensors
Trouble shoot sensor connections and find broken wires with
patented technology. Connect your two, three or four wire RTDs and the PIE
525Plus automatically detects the connections and measures the RTD in degrees C
or F. Secondary display shows the resistance value corresponding to the RTD
temperature. No competitor’s calibrator is compatible with as many process
instruments; also displays excitation current to confirm your RTD transmitter is
working properly.
Calibrate thermocouple
instruments with lab accuracy and stability
The internal cold junction
thermistor is accurate to ±0.05°C and is traceable to NIST. The sensor is
thermally bonded to an isothermal mass including brass blocks with screw
terminals for connection of bare thermocouple wires along with a miniature
thermocouple connector for fast connections. An extremely stable voltage
reference and low drift components make it more accurate than most other
handheld & benchtop thermocouple calibrators. The PIE 525Plus is capable of
meeting the requirements of an AMS 2750 Field Test Instrument when certified by
an accredited laboratory.
Replace thermocouples
before costly failures
Troubleshoot thermocouple probes by measuring the resistance of
the cables and sensing element, allowing you to replace high resistance probes
before they burn out. Open thermocouples and ones with impending failure are
indicated by “OPEN TC” and the resistance value on the 525Plus
display.
Checkout all your 4 to
20 mA loops & instruments
With the built-in milliamp
calibrator you can check, calibrate and measure all your current signal
instruments in a 4 to 20 milliamp loop. It can be used at any access point in
your loop. Source & Read 0.000 to 24.000 mA, Simulate a 2 Wire Transmitter
or use the PIE 525Plus to simultaneously power your 2 Wire Transmitter and
measure its output while simulating the sensor input.
Fast calibration with
automatic output stepping
Choose between 2, 3, 5, 11 and 21
steps to automatically increment the output in 100%, 50%, 25%, 10% or 5% of
span. Select the step time to match your system from 5, 6, 7, 8, 9, 10, 15, 20,
25, 30 and 60 seconds.
Optional
Accessories
Magnet strap(020-0236)
J,K,T & E thermocouple wire
kit(020-0202)
B,R/S &N thermocouple wire kit(020-0203)
구성품
Protective rubber boot
AA Alkaline batteries (four)
Carrying case
Evolution mA/V Wire Kit
Evolution RTD Wire Kit




![[PIE] THERMOCOUPLE & MA CALIBRATOR PIE 525PLUS [PIE] THERMOCOUPLE & MA CALIBRATOR PIE 525PLUS](https://cdn-saas-web-116-121.cdn-nhncommerce.com/naraetek39_godomall_com/data/goods/18/02/06/2310/151788109816m0_detail.jpg)